LMEC-15 Invasio, Diffractio et Velocitas Mensuratio Soni Undarum
Experimenta
1. generare et accipere ultrasound
2. Mensura soni velocitatis in aere utendo tempus et resonantia impedimentum modi
3. Scrutare intercessionem reflexi et undae soni originalis, id est fluctus soni "Lloyd Speculum" experimentum
4. Observa et metire duplices rimulae impedimentum et diffractionem unius soni fluctum
Specifications
Descriptio | Specifications |
Sine signo generantis undam | Frequentia ambitus: 38~ 42 khz.resolutio: 1 hz |
Transducer Ultrasonic | Chipum Piezo-Ceramicum.oscillationis frequentia: 40.1 ± 0.4 khz |
Vernier caliper | Range: 0~ 200 mm.accurate: 0.02 mm |
receptor ultrasonic | Circulus rotationis: -90° ~ 90°.unilateralis: 0° ~ 20°.divisio: 1° |
Mensuratio accurate | <II% ad tempus modum |
Epistulam tuam hic scribe et mitte nobis